On the Effect of Natural Rainfall Variability and Measurement Errors in the Detection of Seeding Effect

1975 ◽  
Vol 14 (5) ◽  
pp. 929-938 ◽  
Author(s):  
Anthony R. Olsen ◽  
William L. Woodley
2015 ◽  
Vol 58 (6) ◽  
pp. 906-914 ◽  
Author(s):  
XiangHua Wu ◽  
ShengJie Niu ◽  
DeZhen Jin ◽  
HaiYan Sun

2010 ◽  
Vol 3 (3) ◽  
pp. 2535-2577 ◽  
Author(s):  
A. Zinevich ◽  
H. Messer ◽  
P. Alpert

Abstract. Commercial microwave radio links forming cellular communication networks are known to be a valuable instrument for measuring near-surface rainfall. However, operational communication links are more uncertain relatively to the dedicated installations since their geometry and frequencies are optimized for high communication performance rather than observing rainfall. Quantification of the uncertainties for measurements that are non-optimal in the first place is essential to assure usability of the data. In this work we address modeling of environmental impairments, i.e. variability of drop size distribution along a link and spatial variability of rainfall in the link's neighborhood, as well as instrumental ones, i.e. signal variability due to antenna wetting, baseline attenuation uncertainty and digital quantization. Expressions for root mean squared error (RMSE) for estimates of path-averaged and point rainfall have been derived. To verify the RMSE expressions quantitatively, path-averaged measurements from 23 operational communication links have been compared to records of five nearby rain gauges over three rainstorm events. It has been demonstrated that the major sources of link-gauge discrepancies are spatial variability and baseline attenuation uncertainty; the former remains important for up to 120 min temporally averaged measurements. The experiments show that the predicted RMSE on the average fit the measured RMSE for various link lengths, rain rates and temporal intervals; above 90% of experimental errors for 1–60 min averages and 88% for 120 min are explained by the model. In addition, the dependence of the optimal coefficients of a conventional wet antenna attenuation model on spatial rainfall variability has been shown. The expressions for RMSE of the path-averaged rainfall estimates can be useful for integration of measurements from multiple heterogeneous links into data assimilation algorithms.


2009 ◽  
Vol 33 (3) ◽  
pp. 307-318 ◽  
Author(s):  
Wei Wei ◽  
Liding Chen ◽  
Bojie Fu

Water erosion is the most destructive erosion type worldwide, causing serious land degradation and environmental deterioration. Against a background of climate change and accelerated human activities, changes in natural rainfall regimes have taken place and will be expected to become more pronounced in future decades. Long-term shifts may challenge the existing cultivation systems worldwide and eventually alter the spatiotemporal patterns of land use and topography. Meanwhile, specific features of soil crusting/sealing, plant litter and its decomposition, and antecedent soil moisture content (ASMC) will accompany rainfall variability. All these changes will increase pressures on soil erosion and hydrological processes, making accurate erosion prediction and control more difficult. An improved knowledge and understanding of this issue, therefore, is essential for dealing with the forthcoming challenges regarding soil and water conservation practices. In this paper, the characteristics of changes in natural rainfall, its role on terrestrial ecosystems, the challenges, and its effect on surface water erosion dynamics are elaborated and discussed. The major priorities for future research are also highlighted, and it is hoped that this will promote a better understanding of water erosion processes and related hydrological issues.


2010 ◽  
Vol 3 (5) ◽  
pp. 1385-1402 ◽  
Author(s):  
A. Zinevich ◽  
H. Messer ◽  
P. Alpert

Abstract. Commercial microwave radio links forming cellular communication networks are known to be a valuable instrument for measuring near-surface rainfall. However, operational communication links are more uncertain relatively to the dedicated installations since their geometry and frequencies are optimized for high communication performance rather than observing rainfall. Quantification of the uncertainties for measurements that are non-optimal in the first place is essential to assure usability of the data. In this work we address modeling of instrumental impairments, i.e. signal variability due to antenna wetting, baseline attenuation uncertainty and digital quantization, as well as environmental ones, i.e. variability of drop size distribution along a link affecting accuracy of path-averaged rainfall measurement and spatial variability of rainfall in the link's neighborhood affecting the accuracy of rainfall estimation out of the link path. Expressions for root mean squared error (RMSE) for estimates of path-averaged and point rainfall have been derived. To verify the RMSE expressions quantitatively, path-averaged measurements from 21 operational communication links in 12 different locations have been compared to records of five nearby rain gauges over three rainstorm events. The experiments show that the prediction accuracy is above 90% for temporal accumulation less than 30 min and lowers for longer accumulation intervals. Spatial variability in the vicinity of the link, baseline attenuation uncertainty and, possibly, suboptimality of wet antenna attenuation model are the major sources of link-gauge discrepancies. In addition, the dependence of the optimal coefficients of a conventional wet antenna attenuation model on spatial rainfall variability and, accordingly, link length has been shown. The expressions for RMSE of the path-averaged rainfall estimates can be useful for integration of measurements from multiple heterogeneous links into data assimilation algorithms.


Author(s):  
W.J. de Ruijter ◽  
Sharma Renu

Established methods for measurement of lattice spacings and angles of crystalline materials include x-ray diffraction, microdiffraction and HREM imaging. Structural information from HREM images is normally obtained off-line with the traveling table microscope or by the optical diffractogram technique. We present a new method for precise measurement of lattice vectors from HREM images using an on-line computer connected to the electron microscope. It has already been established that an image of crystalline material can be represented by a finite number of sinusoids. The amplitude and the phase of these sinusoids are affected by the microscope transfer characteristics, which are strongly influenced by the settings of defocus, astigmatism and beam alignment. However, the frequency of each sinusoid is solely a function of overall magnification and periodicities present in the specimen. After proper calibration of the overall magnification, lattice vectors can be measured unambiguously from HREM images.Measurement of lattice vectors is a statistical parameter estimation problem which is similar to amplitude, phase and frequency estimation of sinusoids in 1-dimensional signals as encountered, for example, in radar, sonar and telecommunications. It is important to properly model the observations, the systematic errors and the non-systematic errors. The observations are modelled as a sum of (2-dimensional) sinusoids. In the present study the components of the frequency vector of the sinusoids are the only parameters of interest. Non-systematic errors in recorded electron images are described as white Gaussian noise. The most important systematic error is geometric distortion. Lattice vectors are measured using a two step procedure. First a coarse search is obtained using a Fast Fourier Transform on an image section of interest. Prior to Fourier transformation the image section is multiplied with a window, which gradually falls off to zero at the edges. The user indicates interactively the periodicities of interest by selecting spots in the digital diffractogram. A fine search for each selected frequency is implemented using a bilinear interpolation, which is dependent on the window function. It is possible to refine the estimation even further using a non-linear least squares estimation. The first two steps provide the proper starting values for the numerical minimization (e.g. Gauss-Newton). This third step increases the precision with 30% to the highest theoretically attainable (Cramer and Rao Lower Bound). In the present studies we use a Gatan 622 TV camera attached to the JEM 4000EX electron microscope. Image analysis is implemented on a Micro VAX II computer equipped with a powerful array processor and real time image processing hardware. The typical precision, as defined by the standard deviation of the distribution of measurement errors, is found to be <0.003Å measured on single crystal silicon and <0.02Å measured on small (10-30Å) specimen areas. These values are ×10 times larger than predicted by theory. Furthermore, the measured precision is observed to be independent on signal-to-noise ratio (determined by the number of averaged TV frames). Obviously, the precision is restricted by geometric distortion mainly caused by the TV camera. For this reason, we are replacing the Gatan 622 TV camera with a modern high-grade CCD-based camera system. Such a system not only has negligible geometric distortion, but also high dynamic range (>10,000) and high resolution (1024x1024 pixels). The geometric distortion of the projector lenses can be measured, and corrected through re-sampling of the digitized image.


2020 ◽  
pp. 66-72
Author(s):  
Irina A. Piterskikh ◽  
Svetlana V. Vikhrova ◽  
Nina G. Kovaleva ◽  
Tatyana O. Barynskaya

Certified reference materials (CRM) composed of propyl (11383-2019) and isopropyl (11384-2019) alcohols solutions were created for validation of measurement procedures and control of measurement errors of measurement results of mass concentrations of toxic substances (alcohol) in biological objects (urine, blood) and water. Two ways of establishing the value of the certified characteristic – mass consentration of propanol-1 or propanol-2 have been studied. The results obtained by the preparation procedure and comparison with the standard are the same within the margin of error.


Sign in / Sign up

Export Citation Format

Share Document